Problem(Abstract)
Optim Exit running pr0sign command failed with challenge module message:
"Challange module /opt/IBM/Optim/rt/bin/libpr0chlg.so is corrupt (9)".
Symptom
Unable to sign the Optim Exit.
Cause
Corrupted ".mw" directory
Resolving the problem
Resolving the challenge module issue requires re-creating the corrupted ".mw" directory.
Here are the suggested steps.
- Delete a hidden folder named ".mw" located at the logged in user's default Optim home directory.
- At the home directory, run "ls -la" from command prompt to locate the folder.
- Remove the ".mw" folder by issuing "rm -r .mw".
Note: Mainwin will create a new .mw folder after steps are done. - Re-sign the Optim exit using "pr0sign -d" with the same user id that installed Optim, and the id that is in a plan to run the Optim server.
http://www-01.ibm.com/support/docview.wss?uid=swg21443476