728x90
Problem(Abstract)
-244 Could not do a physical-order read to fetch next row.
-197 ISAM error: Partition recently appended to; can't open for
write or logging.
Symptom
-244 Could not do a physical-order read to fetch next row.
-197 ISAM error: Partition recently appended to; can't open for
write or logging.
Cause
A High Performance Loader express mode load was run on this table.
Resolving the problem
You must perform a level-0 backup before you can write to the target database. See the Related Information section below for more information regarding express mode load.
http://www-01.ibm.com/support/docview.wss?uid=swg21378086
728x90
'Informix > informix troubleshooting' 카테고리의 다른 글
Collect information when a recovery failure occurs with Informix Dynamic Server (0) | 2015.09.08 |
---|---|
인포믹스 12.10 설치시 오류 (Windows 2012 R2) (0) | 2015.08.05 |
onbar restore중 out of virtual shared memory 오류 (0) | 2015.06.28 |
Message Referencing return code 126 or 127 and alarmprogram.sh in your online.log File (0) | 2015.06.11 |
online.log 에서 SCHAPI Estimate Compression 메시지가 표시되는 경우 (0) | 2015.06.03 |